Process-Gaschromatographs
meta GC-PID III - photoionisation
The compact meta GC-PID III is using a photoionisation detector (PID) to provide a high selectivity for lightly aromatic and halogenated hydrocarbons (LHKW). The systems makes automatic and manual sample task possible. The detectability of the compound depends on the type of the used lamp and the ionisation potential of the substancen which should be analysed. Compounds which have an ionisation potential lower or equal of the used lamp can be detected. We use lamps with 10,6 e.V or 11,6 e.V. . The temperature regulation happens isotherm with 40°C, 60°C or 120°C and a extension with one of our measuring point switch or our water sampling system is possible without problems. The meta GC-PID III is available as a mobil table version or as a stationary rack-version.
Detection limits (selection)
benzene |
C6H6 | 0,01 mg/m³ |
toluoene | C7H8 | 0,01 mg/m³ |
ethyl benzene | C8H10 | 0,01 mg/m³ |
m,p-xylene | 0,01 mg/m³ | |
o-xylene | 0,01 mg/m³ |
Details
Version: | 19" rack or table housing 3 RU |
Dimensions: | 480 x 135 x 400 mm (W x H x D) |
Weight: | approx. 6 kg |
Supply voltage: | 230 VAC/50Hz |
Power consumption: | 0,5 KW |
Moisture: |
0-90% rel. moisture; not condensing |
Temperature range: | 0-40°C |
Protection type: | IP20 / DIN40050 |
Protection class: | 1 |
Environmental condidtions: | dust free |
meta GC-TID - thermoionisation
The meta GC-TID is using a thermoionisation detector (TID) to provide a high selectivity for lightly aromatic and halogenated hydrocarbons (LHKW). The core of the TID is made of a special ceramic, which is wrapped in a platinum wire. This will be heated by aunder tension setted wire and thus a substance relevant ionisation is taking place. The systems makes automatic and manual sample task possible. The meta GC-TID is available as a mobil table version or as a stationary rack-version.
Detection limits (selection)
vinylchloride | C2H3CI | 0,01 mg/m³ |
trichlorethene | C2HCI3 | 0,01 mg/m³ |
tetrachlorethene | C2CI4 | 0,01 mg/m³ |
1,2-dichlorethene | C2H2CI2 | 0,01 mg/m³ |
chlormethane | CH3CI | 0,01 mg/m³ |
Details
Version: | 19" rack or table housing 3 RU |
Dimensions: | 480 x 135 x 400 mm (W x H x D) |
Weight: | approx. 6 kg |
Supply voltage: | 230 VAC/50Hz |
Power consumption: | 0,5 KW |
Moisture: |
0-90% rel. moisture; not condensing |
Temperature range: | 0-40°C |
Protection type: | IP20 / DIN40050 |
Protection class: | 1 |
Environmental condidtions: | dust free |
Detection limits (selection)
methane | CH4 | 0,1 mg/m³ |
ethane | C2H6 | 0,1 mg/m³ |
propane | C3H8 | 0,1 mg/m³ |
butane | C4H10 | 0,1 mg/m³ |
benzene | C6H6 | 0,1 mg/m³ |
Details
Version: | 19" rack or table housing 4 RU |
Dimensions: | 480 x 180 x 400 mm (W x H x D) |
Weight: | approx. 9 kg |
Supply voltage: | 230 VAC/50Hz |
Power consumption: | 0,5 KW |
Moisture: |
0-90% rel. moisture; not condensing |
Temperature range: | 0-40°C |
Protection type: | IP20 / DIN40050 |
Protection class: | 1 |
Environmental condidtions: | dust free |
meta GC-WLD - thermal conductivity detector
The meta GC-WLD makes automatic and manual sample task possible. The WLD consist of a measuring- and a reference-cell, which build a bridge circuit. When the carrier gas is flowing through the system are the measuring- an reference-cell in a rest mode. A change of the overall condition caused a temperature change and therefor a resistor change of the wire in the measuring cell. The resulting voltage diffrence will be measured and evaluated. The system reacts seletcive of organic and anorganic hydrocarbons.
Detection limits (selection)
carbon monoxid | CO | |
carbon dioxid | CO2 | |
oxygen | O2 | |
hydrogen | H2 | |
helium | He |
Details
Version: | 19" rack or table housing 3 RU |
Dimensions: | 480 x 135 x 400 mm (W x H x D) |
Weight: | approx. 6 kg |
Supply voltage: | 230 VAC/50Hz |
Power consumption: | 0,5 KW |
Moisture: |
0-90% rel. moisture; not condensing |
Temperature range: | 0-40°C |
Protection type: | IP20 / DIN40050 |
Protection class: | 1 |
Environmental condidtions: | dust free |
meta GC-PID/TID - photo- & thermoionisation
The meta GC-PID/TID is the perfect solution to combine both advanteges of the photo- and thermoionisation. This GC combines both detectors and can cover a bigger spectrum of compounds.
Details
Version: | 19" rack or table housing 3 RU |
Dimensions: | 480 x 135 x 400 mm (W x H x D) |
Weight: | approx. 6 kg |
Supply voltage: | 230 VAC/50Hz |
Power consumption: | 0,5 KW |
Moisture: |
0-90% rel. moisture; not condensing |
Temperature range: | 0-40°C |
Protection type: | IP20 / DIN40050 |
Protection class: | 1 |
Environmental condidtions: | dust free |
Summation-FID - flameionisation
As exclusive distributer of usual Summation-FIDs we can also offer our customers a measuring system which can analyse all compustible hydrocarbons in summation. For technichal details please contact us.